EC number: 411-470-5 | CAS number: 141048-13-7 NAVY 14 05 711
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Emergency measure - Inhalation: Move the exposed person to fresh air. In case of
indisposition seek medical advice.
Emergency measure - Eyes: Rinse with plenty of water. If irritation occurs,
seek medical advice.
Emergency measure - Skin: Wash with soap and water.
Emergency measure - Ingestion: Symptomatic treatment. In case of indisposition
seek medical advice.
Fire-fighting measures
Recommended extinguishing agent: Water, foam, dry powder, CO2.
Product arising from burning: Substance itself does not present a fire hazard. If involved
in a fire , mainly nitric oxides, carbon oxides as well as
sulfur-, copper-, chlorine- and sodium compounds may be
produced (derived from the structure).
Product determined by test: N
Protective equipment: Self contained breathing apparatus should be used.
Accidental release measures
Emergency measures in case of spillage: During handlinq and destruction of the substance, wear dust
mask, suitable goggles, impermeable gloves and protective
clothing.
For dry residues, collect and dump in licensed landfill
site or discharge by incineration in suitable plant. For
spillage absorb with adequate absorber and discharge by
incinerationin suitable plant or by dumping in licensed
landfill site.
The labelling of the containers filled with the substance
to be destroyed should indicate the danger of the substance.
Handling and storage
Handling: The usual precautions for the handling with chemicals should
be observed. Avoid any contact and wear impermeable gloves.
If the substance is handled as a powder, avoid dust
formation and wear dust mask. Dust-proof filling apparatus
or appropriate exhaust system should then be used.
Storage: The containers should be stored tightly closed in
unbreakable containers in adequate rooms.
Avoid residues of the product outside the containers.
Packaging of the substance and or preparation: The commercial preparation is supplied in 25 kg containers.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: Not classified
Transport: The product will be shipped in adequate, tightly closed
containers e.g. in polyethylene bags in sealed steeldrums.
Avoid unintentional spilling of the substance by taking
adequate precautions.
The containers have to be labelled according to the
pertinent regulations.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Danger other than fire: None.
Chemical reaction with water: Not known.
Dust explosion: Not to be expected if handled under usual industrial hygiene
practices.
Dust explosion determined by test: N
Disposal considerations
Industry - Possibility of recovery/recycling: Normal application results in the consumption of 63% by
irreversible binding to textiles.
Recovery for recycling of the remaining highly water soluble
substance is not possible.
Industry - Possibility of neutralisation: No possibilities known.
Industry - Possibility of destruction: controlled discharge: Discharge in a controlled deposit is possible.
Industry - Possibility of destruction - incineration: Discharge by incineration in suitable plant is possible.
Industry - Possibility of destruction - water purification: It is estimated that approximately 37% of the total quantity
used is discharged into internal industrial effluents as a
diluted solution. A purification of the waste water is
absolutely necessary. This substance can only be used in a
well equipped dye house.
The waste water can be purified by membrane filtration or by
floculation with cationic agents or by treatment with
ozone.
The most effective method is the membrane filtration: more
than 99% of the dyestuff can be removed from the waste
water.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.