Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to EU / OECD-guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
methyl 4-cyano-2-nitrobenzoate
EC Number:
610-840-5
Cas Number:
52449-76-0
Molecular formula:
C9H6N2O4
IUPAC Name:
methyl 4-cyano-2-nitrobenzoate

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The test item began to melt immediately after it was tried to ignite the pile with a hot flame from a gas burner. There was no inflammation observed within 2 minutes.

Because it was impossible to ignite the test item the main test had not to be performed.

Therefore the test item is classified to be not inflammable according to EEC-Guideline A.10.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test item is classified to be not inflammable according to EEC-Guideline A.10.