Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 208-591-9 | CAS number: 534-17-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
Two studies (in vitro and in vivo) are available for skin irritation and one in vitro study for eye irritation.
OECD Guideline 431: the conclusion of the study was that the test item is considered to be not corrosive to the skin.
OECD Guideline 404: the conclusion of the study was that the test item (50 % solution) is considered as a negligible irritant to the skin.
OECD Guideline 437: the conclusion of the study was that the test item is considered as eye damaging.
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vivo
- Type of information:
- not specified
- Adequacy of study:
- weight of evidence
- Study period:
- Final report : Dec. 17th, 2003
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- Main deficiency: Test material was Cesium carbonate 50% solution
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 404 (Acute Dermal Irritation / Corrosion)
- GLP compliance:
- yes
- Specific details on test material used for the study:
- Cesium carbonate 50% solution
- Irritation parameter:
- edema score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- erythema score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Remarks on result:
- no indication of irritation
- Interpretation of results:
- GHS criteria not met
- Executive summary:
The test article, cesium carbonate 50% solution, was evaluated for its potential to produce primary dermal irritation or corrosion after a single topical 4 hour application to the skin of New Zealand White rabbits. The test article is considered a negligeable irritant.
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 2010-07-02 to 2010-07-03
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Human Skin Model Test)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Justification for test system used:
- The EPISKIN model has been validated for corrosivity testing in an international trial; it is considered to be suitable for this study (STATEMENT ON THE SCIENTIFIC VALIDITY OF THE EPISKINTM TEST (AN IN VITRO TEST FOR SKIN CORROSIVITY); ECVAM JRC Environment Institute, European Commission; Ispra; 03 April 1998).
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm ™
- Tissue batch number(s): 13657
- Delivery date: 01. Jul. 2010
- Date of initiation of testing: 02. Jul. 2010
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37 °C
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- Incubation time: 3 hours
- Spectrophotometer: plate spectral photometer Dynatech MRX
- Wavelength: 570 nm
NUMBER OF REPLICATE TISSUES: 2
NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION:
PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.
- The test substance is considered to be non-corrosive to skin if the viability after 3 minutes exposure is greater than 50% and the viability after 1 hour exposure is greater than 15%. - Control samples:
- yes, concurrent vehicle
- yes, concurrent positive control
- Amount/concentration applied:
- 59 mg
- Duration of treatment / exposure:
- 3 min, 1 h
- Number of replicates:
- 2
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Negative control (3 min and 1 h)
- Value:
- 100
- Vehicle controls validity:
- valid
- Negative controls validity:
- not examined
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Remarks:
- (OD570 = 1.598)
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Positive control (1 h)
- Value:
- 20.3
- Vehicle controls validity:
- valid
- Negative controls validity:
- not examined
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Remarks:
- (OD570 = 0.325)
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Test item (1 h)
- Value:
- 47.4
- Vehicle controls validity:
- valid
- Negative controls validity:
- not examined
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Remarks:
- (OD570 = 0.757)
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Test item (3 min)
- Value:
- 102.6
- Vehicle controls validity:
- valid
- Negative controls validity:
- not examined
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Remarks:
- (OD570 = 1.656)
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Positive control (3 min)
- Value:
- 25.5
- Vehicle controls validity:
- valid
- Negative controls validity:
- not examined
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Remarks:
- (OD570 = 0.411)
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- According to OECD Guideline 431 study the test item is considered to be not corrosive.
- Executive summary:
The test item is considered to be not corrosive. After three minutes treatment, the relative absorbance values were decreased to 102.6 %. This value is well above the threshold for corrosivity (50 %). After one hour treatment relative absorbance values were reduced to 47.4 %. This value is well above the threshold for corrosivity (15 %). The values of the negative control were well above the required acceptability criterion of mean OD > 0.8 for both treatment interval thus showing the quality of the tissues. The value of the positive control induced a decrease in the relative absorbance as compared to the negative control to 25.5 % for the three minutes treatment interval and 20.3 % for the one hour treatment interval thus ensuring the validity of the test system. Although the value of the one-hour-experiment was 20.3 % and therefore higher than the threshold for corrosivity, this is considered as not relevant, as a clear corrosive effect was determined and values above 15 % have been measured for the positive control before: Values for the positive control were within the range of historical data of the test facility.
Referenceopen allclose all
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2015-02-12 to 2015-02-12
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP and guideline compliant study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Species:
- other: bovine
- Details on test animals or tissues and environmental conditions:
- Isolated corneas obtained as a by-product from a slaughterhouse were used after examination for defects. They were mounted in corneal holders with endothelial side against the O-ring of the posterior chamber. After treatment with RPMI an opacity measurement was performed using an opacitometer to discarded corneas that have an initial opacity reading above 7 units. Three corneas with opacity readings approximately equivalent to the median opacity were selected as negative-controll. For testing 750 µL of test item or control substance were used (closed-chamber method). After incubation time substances were removed and the epithelium was washed with MEM (RPMI was used for the controll group). The anterior chamber was refilled with complete RPMI and the opacity measurement was performed. In addition optical density at 490 nm was determined using a spectrophometer. Therefore the poserior chamber was refilled with complete RPMI and the anterior chamber with 1 ml of 5 mg/ml sodium fluorescein solution. After the incubation time of 90 min at 32 +- 1°C the optical density was measured. After that the in vitro irritation score (IVIS) was determined with following formula: mean opacity value + (15 x mean permeabiltiy optical densitiy at 490 nm.
- Vehicle:
- physiological saline
- Amount / concentration applied:
- The test item was suspended with physiological saline 0.9% NaCl (see 10.3) to gain a
20% concentration. - Duration of treatment / exposure:
- 4 hours +- 5 min to measure the opacity.
90min to measure the optical density at 490 nm. - Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Mean
- Value:
- 183.05
- Vehicle controls validity:
- valid
- Negative controls validity:
- not examined
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Interpretation of results:
- Category 1 (irreversible effects on the eye) based on GHS criteria
- Remarks:
- Migrated information
- Conclusions:
- According to the evaluation criteria the test item cesium carbonate is classified into UN GHS Category 1.
- Executive summary:
The eye irritancy potential of cesium carbonate was investigated in the bovine corneal opacity and permeability assay.The study followed the procedures indicated by OECD Guideline for the Testing of Chemicals, number 437 “Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage”. Therefore the test item cesium cabonate was suspended with physiological saline 0.9% NaCl to gain a 20% concentration. The mean in vitro irritation score was calculated at 183.05. Therefore the test item was classified into UN GHS Category 1. The in vitro irritation score obtained with the positive control fell within the two standard deviations of the current historical mean and therefore this assay is considered to be valid.
Reference
Endpoint conclusion
- Endpoint conclusion:
- adverse effect observed (irreversible damage)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Skin irritation
in vitro
One valid experiment was performed in accordance with OECD guideline 431. Two tissues of the human skin model EpiDerm™ were treated with Cesium Carbonate for three minutes and one hour, respectively. ln average 59 mg of the solid test item were applied to each tissue and spread to match the tissue size. Deionised water was used as negative control, Sm KOH was used as positive control. After treatment with the negative control the absorbance values were weil above the required acceptability criterion of mean 00 > 0.8 for both treatment intervals thus showing the quality of the tissues. The positive control showed clear corrosive effects for both treatment intervals. After three minutes treatment with the test item, the relative absorbance values were increased to 102.6 %. This value is weil above the threshold for corrosion potential (50 %). After one hour treatment, relative absorbance values were reduced to 47.4 %. This value, too, is weil above the threshold for corrosion potential (15 %). Therefore, cesium carbonate is considered as not corrosive in the Human Skin Model
Test.
in vivo
The test article, cesium carbonate 50% solution, was evaluated for its potential to produce primary dermal irritation or corrosion after a single topical 4 hour application to the skin of New Zealand White rabbits. The test article is considered a negligable irritant.
Eye irritation
The eye irritancy potential of cesium carbonate was investigated in the bovine corneal opacity and permeability assay according to OECD guideline 437. The test item was suspended with physiological saline 0.9% NaCl to gain a 20% concentration. The mean in vitro irritation score was 185.05. The in vitro irritation score obtained with the positive control fell within the two standard deviations of the current historical mean and therefore this assay is considered to be valid. According to the evaluation criteria the test item cesium carbonate is regarded as eye damaging (cat 1 if IVIS scorre is above 55).
Justification for classification or non-classification
The test item was not corrosive in an in vitro skin corrosion study according to OECD 431. In addition, an in vivo study performed according the OECD guideline 404 concluded that Cesium carbonate 50% solution was considered as a negligible irritant. Therefore, cesium carbonate was not classified as skin irritant.
The test item was corrosive in an in vitro eye corrosion study according to OECD 437 “Bovine Corneal Opacity and Permeability Test" and was classified with Cat. 1 for serious eye damage according to Regulation (EC) No 1272/2008 (CLP/GHS).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.