Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Determination of spectral data and physico-chemical properties followed OECD guidelines.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
not specified
Principles of method if other than guideline:
The viscosity of the liquids is measured using a stress-controlled rotational rheometer (Paar-Physica UDS 200) fitted with a concentric cylinder system. Samples with low viscosities are measured with a double-gap (22.25/22.75; 23.5/24.0 mm) system whereas high viscosity liquids are measured with a cone plate or single gap (12.5/13.56 mm) device. A few measurements are conducted over a shear rate range between 1 and 100 s-1. When the flow is Newtonian (i.e. the viscosity is independent of shear rate), which is usually the case for acrylate resins, the viscosity is returned at 20 or 100 s-1. The temperature is 23.0 °C and is controlled within 0.1°C.
GLP compliance:
no
Type of method:
other: Rotational rheology
Key result
Temp.:
other: 23.0°C
Parameter:
other: Pa.s
Value:
348

Sample #

Viscosity at 1 s-1

Viscosity at 10 s-1

Viscosity at 20 s-1

Viscosity at 100 s-1

Temperature

 

Pa-s

Pa-s

Pa-s

Pa-s

°C

OM0005 EB3608 at 23°C

349

349

348

-

23.0

OM0005 EB3608 at 60°C

2.46

2.47

2.47

2.47

60.0

Conclusions:
Under the study conditions, the viscosity of  EB3608 is 348 Pa.s at 23°C.
Executive summary:

The viscosity of the test substance was determined according to OECD 114 guideline (Cytec, 2011)

Description of key information

The viscosity was determined according to OECD Guideline 114 (Cytec, 2011)

Key value for chemical safety assessment

Viscosity:
348 000 mPa · s (dynamic)
at the temperature of:
23 °C

Additional information