Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16/06/2021 - 24/06/2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-[4-[(dimethylamino)methyl]-3-phenyl-1H-pyrazol-1-yl]-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Cas Number:
1903009-55-1
Molecular formula:
C27H30N8O4
IUPAC Name:
4-[4-[(dimethylamino)methyl]-3-phenyl-1H-pyrazol-1-yl]-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
Batch (Lot) Number: I20HD2581
Purity: 97.1%
Purity/Composition correction factor: 1.00
Expiry date: 15 August 2022
Physical Description: Yellow powder

STORAGE CONDITIONS
Storage Conditions: At room temperature

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Remarks:
The test item was observed to exhibit no reaction at 40J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Remarks:
The test item was observed to exhibit no reaction at 360 N
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Remarks:
The test item did not exhibit an explosion during any of the tests.

Any other information on results incl. tables


  1. BAM FALLHAMMER: Test Procedure


The test item was placed in the impact device and the 10 kg weight dropped from a height of 40 cm which is equivalent to 40 J. If an "explosion" was observed, the impact energy was reduced to 7.5 J and further tests conducted.



















Mass (kg)Height (m)Energy (J)Test number and result* (X / ✓)Comments
10 0.4 40 

1 2 3 4 5 6


X X X X X X 


Decomposition observed
(changed to orange colour)

* ‘✓’ denotes an explosion (includes crackling, sparking, inflammation).
‘X’ denotes no reaction or decomposition (change in colour).


2. BAM FRICTION: Test procedure


The test item was placed on the porcelain plate and the peg lowered. A load of 360 N was then applied and the switch operated. If an "explosion" was observed, the load applied was lowered to 120 N and further tests conducted.

















Mass (kg)Load (N)Test number and result* (X / ✓)Comments
10 360

1 2 3 4 5 6


X X X X X X 


Decomposition (changed to dark
yellow colour)

* ‘✓’ denotes an explosion (includes crackling, sparking, inflammation).
‘X’ denotes no reaction or decomposition (change in colour).


3. KOENEN TUBE: Test procedure















































Mass of test item (g)Orifice Diameter (mm)Time for First Ignition (s) Explosion (X✓)*
13.3615X
13.3616X
13.3614X
13.3213X
13.3212X
13.3212X

* ‘✓’ denotes 3 or more fragments.
‘X’ denotes fewer than 3 fragments.

Applicant's summary and conclusion

Conclusions:
BAM FALLHAMMER:
The test item of JNJ-73848268-AAA (T003903) was observed to exhibit no reaction at 40 J. The test result is therefore considered Negative (-) (according to the EC Classification, Packaging & Labelling of Dangerous Substances in the European Union Part 2, Testing Methods, Jan 97).

BAM FRICTION:
The test item of JNJ-73848268-AAA (T003903) was observed to exhibit no reaction at 360 N. The test result is therefore considered Negative (-) (according to the EC Classification, Packaging & Labelling of Dangerous Substances in the European Union Part 2, Testing Methods, Jan 97).

KOENEN TUBE: