Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019-2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Principles of method if other than guideline:
Not applicable.
GLP compliance:
yes (incl. QA statement)
Remarks:
Inspected on 15-16/11/2017, Signed on 15/05/2018
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
25.5 °C
Atm. press.:
101 kPa

Findings

-Pre-Test for Safety

All observations are presented in the following table.

All observations were made on the surface due the dark colour of the test item.

Table: observations of safety Pre-test

Observations

Temperatures in °C

Small bubbles visible on surface

100

More Bubbles visible on surface

115

More bubbling

Since 120

Boiling on the surface

130

Boiling, gas burner turned off

140

 After cooling down the appearance of the test item was visually unchanged.

-Determination of the Flash Point

The results of the determinations are presented in the following tables.

Table: Findings

Program

Expected flash point (setting)

in °C

Flash point (found)
in °C

Mean
in °C

Notes

Search

140

25.5**

 

not used for calculation (pre-test)

EN ISO 2719-B

25.0*

25.5

25.5

difference < 2 K

EN ISO 2719-B

25.0*

25.5**

 The measurements were conducted on 18. Apr. 2020.

*The test vessel with the test item was precooled to 8.0 °C for the first determination and to 8.7 °C for the second determination.

**Flame was visible

Evaluation and Result

The flash point is given as the mean value of the duplicate determination. The measured flash point is therefore 25.5 °C (corresponding to 298.7 K).

 

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The measured flash point is therefore 25.5 °C (corresponding to 298.7 K).
 
Executive summary:

The flash point of the test substance was determined under GLP according to ISO 2719:2003 (listed in EU Method A9), a non-equilibrium closed cup method.

A pre-test and a main study with two experiments were performed. The flashpoint value is the mean value of two independent valid determinations.

Description of key information

The measured flash point is therefore 25.5 °C (corresponding to 298.7 K).

The substance is classified according to Regulation (EC) N°1272/2008 (CLP) criteria and is classified as Flammable Liquid (Category 3).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
25.5 °C

Additional information

The flash point of the test substance was determined under GLP according to EU Method A.9 (Flash-Point), using a non-equilibrium closed cup method (ISO2719 -B). It is considered as a key study.