Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 March 2000 to 09 March 2000
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2000
Report date:
2000

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethyl 6,8-dichlorooctanoate
EC Number:
435-080-1
EC Name:
Ethyl 6,8-dichlorooctanoate
Cas Number:
1070-64-0
Molecular formula:
C10H18Cl2O2
IUPAC Name:
ethyl 6,8-dichlorooctanoate
Test material form:
liquid
Specific details on test material used for the study:
Batch: Ds 1099

Results and discussion

Vapour pressure
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
0.045 Pa

Applicant's summary and conclusion

Conclusions:
6,8 DEC has a vapoour pressure of 4.5 x 10-2 Pa at 25°C, using a vapour pressure balance.
Executive summary:

6,8 DEC has a vapoour pressure of 4.5 x 10-2 Pa at 25°C, using a vapour pressure balance.