Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Study period:
1994
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles.
Qualifier:
no guideline followed
Principles of method if other than guideline:
Extrapolated from published literature.
GLP compliance:
no
Remarks:
non GLP certified lab
Conclusions:
The calculated flammability range was 0.6 to 7.0%, the range was extrapolated from published literature.
Executive summary:

The calculated flammability range was 0.6 to 7.0%, the range was extrapolated from published literature.

Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid

Description of key information

The calculated flammability range is 0.6 to 7.0 %v/v. 

Key value for chemical safety assessment

Additional information

Justification for classification or non-classification

Flash point is above 61°C.