Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01Mar2018 to 13Mar2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D7094. Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other:
Remarks:
Eraflash Flash-Point Tester
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Lot 20160912
- Purity: 99.2%
- Expiration date of the lot/batch: 1-August-2018
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature
- Stability under test conditions: test substance stable
Key result
Flash point:
10 °C
Atm. press.:
1 013.25 hPa
Interpretation of results:
Category 2 (highly flammable liquids) based on GHS criteria
Conclusions:
MTDID 49220 has a flash point of 10 °C at standard pressure (1013.25 hPa), determined with a closed-cup tester according to ASTM D7094.
Executive summary:

MTDID 49220 has a flash point of 10 °C at standard pressure (1013.25 hPa), determined with a closed-cup tester according to ASTM D7094. The study was conducted in accordance with an accepted international standard and was GLP compliant; therefore the study is considered reliable without restrictions.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
secondary literature
Remarks:
Data from an SDS. No details provided.
Qualifier:
no guideline available
Principles of method if other than guideline:
no information regarding method available
Key result
Flash point:
7 °C
Conclusions:
A flash point of 7 °C was reported for MTDID 49220 on a Safety Data Sheet.
Executive summary:

A flash point of 7 °C at an unreported atmospheric pressure was reported for MTDID 49220 on a Safety Data Sheet. No information was available regarding the method used to measure the flash point and therefore the reliability of this result is not assignable.

Description of key information

MTDID 49220 has a flash point of 10 °C at standard pressure (1013.25 hPa), determined with a closed-cup tester according to ASTM D7094.

Key value for chemical safety assessment

Additional information

The study was conducted in accordance with an accepted international standard and was GLP compliant; therefore the study is considered reliable without restrictions. Another flash point value was reported in a source for which reliability could not be assigned; this value is not considered further.