flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07.11.2007 to 16.06.2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Batch No. 11270191004
Glycerol dimethacrylate: 89.3%
1.0 % Glycerol monomethacrylate: 1.0 %
Rest: 1-4 fold unsaturated adducts of glycerol
Methacrylic acid: 0.64 %
Hydroquinone monomethylether: 785 pp (stabilizer)

Storage conditions: between 4 °C and room temperature
Key result
Flash point:
153 °C
Atm. press.:
1 013.25 mBar
Conclusions:
The flash point of the test item was determined to EU test method A9 [Directive 92/69/EEC,
Official Journal L 383 A 1992] with the Pensky-Martens method, ASTM D 93 (closed-up)
Flash point : 153 °C
Executive summary:

The flash point of the test item was determined to EU test method A9 [Directive 92/69/EEC, Official Journal L 383 A 1992] with the Pensky-Martens method, ASTM D 93 (closed-up)

Flash point : 153 °C

Description of key information

153 °C at 1.013 hPa (EEC A9: Pensky-Martens method, ASTM D 93 (closed-cup))

Key value for chemical safety assessment

Flash point at 101 325 Pa:
153 °C

Additional information