Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 284-748-5 | CAS number: 84962-50-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- March from 01 to 05, 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with generally accepted scientific standards and described in sufficient detail
- Reason / purpose for cross-reference:
- reference to other study
- Remarks:
- validated analytical method
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Version / remarks:
- adopted July 27, 1995
- Deviations:
- yes
- Remarks:
- The stock solution of the test item was prepared in water saturated with n-octanol. This procedure deviates from the guideline, but is considered scientifically valid.
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- flask method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Type:
- Pow
- Partition coefficient:
- 0.144
- Temp.:
- 20 °C
- pH:
- ca. 6.75
- Type:
- log Pow
- Partition coefficient:
- -0.848
- Temp.:
- 20 °C
- pH:
- ca. 6.75
- Conclusions:
- log Pow: -0.85 at 20 °C and pH ca 6.75
- Executive summary:
The partition coefficient of the test item was determined usingshake-flask method,in accordante with the method and procedures outlined into the OECD guideline 107. The concentration in the aqueous and octanol phases was determined by HPLC-UV validate method. On the basis of the preliminary assay, the value of the partition coefficient was estimated to be 0.002.
Three experiments were carried out applying different solvent ratios.
In the first experiment, the calculated volume ratio was applied, in the second, this ratio is divided by two and in the third, this ratio is multiplied by two. Test temperature was 20 ± 1 °C. Three parallel tests were carried out at all solvent ratios in 15 ml centrifuge tubes. The test vessels were shaken by hand through 180 ° about its transverse axis, hundred times during five minutes.
The partition coefficient (Pow) was determined to be 0.14, corresponding to the log Pow -0.85, at 20 °C and pH ca 6.75.
Conclusion
log Pow: -0.85 at 20 °C and pH ca 6.75
Reference
Calculated partition coefficient (Pow) and logPow
Ratio of solvents (n-Octanol: : water) | Partition coefficient (Pow) | Log Partition coefficient (Log Pow) | pH |
01:01 | 0.133 | -0.880 | 6.76 |
01:02 | 0.169 | -0.771 | 6.76 |
02:01 | 0,129 | -0.893 | 6.73 |
Mean all | 0.144 | -0.848 | 6.75 |
Measured concentrations
Ratio of solvents (n-Octanol: water ) | Measured concentration in n-octanol phase (µg/ml) | Measured concentration in aqueous phase (µg/ml) | pH |
01:01 | 116 | 917.2 | 6.76 |
110.9 | 931.7 | 6.76 | |
144.2 | 946.4 | 6.76 | |
Mean (C) |
123.7 | 931.8 | 6.76 |
RSD% | 15 | 2 | - |
Meas. test item (Mo, Mw) |
0.928 mg | 6.988 mg | - |
Total quantity of test item (Mo+Mw) in the two-phase system: |
7.916 mg | ||
Total nominal quantity of test item (Ms) | 7.538 mg | ||
Recovery: | 105 % | ||
01:02 | 122.2 | 736.6 | 6.76 |
132.4 | 747 | 6.77 | |
121 | 733.6 | 6.77 | |
Mean (C) |
125.2 | 739.1 | 6.76 |
RSD% | 5 | 1 | - |
Meas. test item (Mo, Mw) | 0.626 mg | 7.391 mg | - |
Total quantity of test item (Mo+Mw) in the two-phase system: | 8.017 mg | ||
Total nominal quantity of test item (Ms) | 7.538 mg | ||
Recovery: | 106 % | ||
02:01 | 147.4 | 1293.9 | 6.73 |
184.9 | 1269.3 | 6.73 | |
160.4 | 1266.9 | 6.73 | |
Mean (C) | 164.2 | 1276.7 | 6.73 |
RSD% | 12 | 1 | - |
Meas. test item (Mo, Mw) | 1.642 mg | 6.384 mg | - |
Total quantity of test item (Mo+Mw) in the two-phase system: | 8.026 mg | ||
Total nominal quantity of test item (Ms) | 7.538 mg | ||
Recovery: | 106 % |
Description of key information
log Pow: -0.85 at 20 °C and pH ca 6.75
Key value for chemical safety assessment
- Log Kow (Log Pow):
- -0.85
- at the temperature of:
- 20 °C
Additional information
OECD 107 - shake-flask method
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.