EC number: 236-291-8 | CAS number: 13282-70-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2015-01-19 to 2015-07-23
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- Version / remarks:
- 2010
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Analytical monitoring:
- no
- Details on sampling:
- - Concentrations: 10, 100, 1000 mg/L (nominal)
- Sampling method: After 3 hours, a standard BOD measuring bottle was filled from the contents, the respiration rate was measured for 10 minutes or until the dissolved oxygen level reached 2 mg/L.
- Sample storage conditions before analysis: - Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: The test substance dissolved in deionised water to make a stock solution.
- Controls: Prepared the same way as test samples but without the test substance.
- Chemical name of vehicle (organic solvent, emulsifier or dispersant):NA
- Concentration of vehicle in test medium (stock solution and final test solution(s) or suspension(s) including control(s)):
- Test concentration separation factor: NA
- Evidence of undissolved material (e.g. precipitate, surface film, etc.):NA - Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Laboratory culture:No
- Name and location of sewage treatment plant where inoculum was collected: Chengdong, China (Batch No.: AS201503171)
- Method of cultivation: NS
- Preparation of inoculum for exposure:The sludge was washed three times with deionised water (it was centrifuged for 10 minutes, the supernatant decanted, then the remaining sludge solids resuspended in deionised water), then the wet solids were homogenised in a blender and suspended in deionised water. The sludge suspension was aerated overnight at 20±2 degrees Celsius at pH 7.34.
- Initial biomass concentration: 3 g/L - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 3 h
- Test temperature:
- 18-22 degrees Celsius
- pH:
- 6.5 - 7.51
- Dissolved oxygen:
- NS
- Salinity:
- NS
- Conductivity:
- NS
- Nominal and measured concentrations:
- 10, 100 and 1000 mg/L; the concentrations not measured.
- Details on test conditions:
- TEST SYSTEM
- Test vessel: 1 Litre beakers
- Material, size, headspace, fill volume: 1 Litre beakers, total volume of each reaction 500 ml
- Aeration: 0.8 litres per minute using a Pasteur pipette and an aeration device
- No. of vessels per concentration (replicates): 1 for 10 and 100 mg/L, 3 for 1000 mg/L
- No. of vessels per control (replicates):2
- No. of vessels per vehicle control (replicates): NA
- No. of vessels per abiotic control (replicates):1
- Sludge concentration (weight of dry solids per volume): 3 g/L
- Nutrients provided for bacteria: A synthetic sewage feed was provided (16 g peptone, 11 g meat extract, 3 g urea, 0.7 g NaCl, 0.4 g CaCl2 2H20, 0.2 g MgSO4 7H2O, 2.8 g K2HPO4. 16 mL of this was provided at the beginning of the experiment.
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: water was purified using Milli-Q (Millipore, USA) apparatus
- Particulate matter: Not measured
OTHER TEST CONDITIONS
- Adjustment of pH: No
- Photoperiod:NS
- Light intensity:NS
- Details on termination of incubation:NA (respiration rate was measured directly in vessel)
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
TEST CONCENTRATIONS
- Spacing factor for test concentrations:NA
- Justification for using fewer concentrations than requested by guideline:NA
- Range finding study: Yes
- Test concentrations: 10, 100, 1000 mg/L
- Results used to determine the conditions for the definitive study: No (The range finding study qualified as a limit test, measured EC50 was >1000 mg/L) - Reference substance (positive control):
- yes
- Remarks:
- The microbial inoculums were exposed to 3,5-dichlorophenol at concentrations of 3, 10 and 30 mg/L
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks on result:
- other:
- Details on results:
- - Any observations (e.g. precipitation) that might cause a difference between measured and nominal values: No
- Adsorption (e.g. of test material to the walls of the test container): NS
- Blank controls oxygen uptake rate: 36.2 and 32.7 mg O2/L h
- Coefficient of variation of oxygen uptake rate in control replicates: Relative difference between the negative controls was 9.97% (within the 30% allowed by guidelines)
The results can be seen in Table in the "Any other information on results incl. tables" section. The EC50 for the test substance was established as >1000 mg/L. - Results with reference substance (positive control):
- - Results with reference substance valid? Yes
- Relevant effect levels: 3h EC50 of 3,5 dichlorophenol was calculated to be 4.60 mg/L (95% CR of 10.6 - 15 mg/L), which was within the range of 2-25 mg/L allowed by guidelines. - Validity criteria fulfilled:
- yes
- Remarks:
- The oxygen uptake of the negative controls were 24.1 and 21.8 O2/g h (after considering the sludge concentration of 1.5 g/L) which fulfilled the validity criteria of no less than 20 mg O2/g h.
- Conclusions:
- The effects on the test item to the activated sludge respiration inhibition were investigated in a static test according to OECD 209 guidelines. Under the experimental conditions and based on nominal concentrations, the 3h-EC50 value was determined to be greater than 1000 mg/L.
- Executive summary:
This study was performed to assess the effects on the test item to the activated sludge respiration inhibition according to OECD Test Guideline 209 with GLP compliance.
The respiration rate of an activated sludge fed with a standard amount of synthetic sewage feed was measured after a contact time of three hours. The respiration rate of the same activated sludge in the presence of 10, 100 and 1000 mg/L of test substance under otherwise identical conditions was also measured. The inhibitory effect of the test item at a particular concentration was expressed as a percentage difference from the mean respiration rates of the two controls. It was found that no significant inhibition of respiration was caused by the test substance.
Under the experimental conditions and based on nominal concentrations, the 3h-EC50 value was determined to be >1000 mg/L.
Reference
Table. Respiration Inhibition Range finding test | ||||||
Beakers | Con. (mg/L) | O2 Concentration | Time (s) | Oxygen consumption rate mg O2/L h | % Inhibition | |
Upper Value | Lower Value | |||||
1 Abiotic Control | 1056 | 7.35 | 7.32 | 600 | 0.18 | - |
2. Neg. Control | 0 | 6.50 | 2.00 | 448 | 36.2 | - |
3 Test | 9.63 | 6.50 | 2.00 | 379 | 42.7 | -24.1 |
4 Test | 96.3 | 6.50 | 2.00 | 610 | 26.6 | 22.9 |
5 Test | 1056 | 6.00 | 2.00 | 645 | 22.3 | 35.2 |
6 Test | 1056 | 5.50 | 2.00 | 569 | 22.1 | 35.7 |
7 Test | 1056 | 6.00 | 2.00 | 635 | 22.7 | 34.2 |
8 Pro. Control | 3 | 6.50 | 2.00 | 512 | 31.6 | 8.15 |
9 Pro. Control | 10 | 5.00 | 2.00 | 548 | 19.7 | 42.8 |
10 Pro. Control | 30 | 5.90 | 4.70 | 600 | 7.20 | 79.1 |
11 Neg. Control | 0 | 5.50 | 2.00 | 385 | 32.7 | - |
EC50 value of Test | >1000 mg/L | 95% confidence limit | - | |||
EC50 value of Reference | 4.60 mg/L | 95% confidence limit | 3.70 ~ 5.72 mg/L |
Description of key information
3 h NOEC = >1000 mg/L (Activated sludge respiration), OECD 209 (2010); Linjun, Z. (2015)
Key value for chemical safety assessment
- EC10 or NOEC for microorganisms:
- 1 000 mg/L
Additional information
The key study was performed to assess the effects on the test item to the activated sludge respiration inhibition according to OECD Test Guideline 209 with GLP compliance.
The respiration rate of an activated sludge fed with a standard amount of synthetic sewage feed was measured after a contact time of three hours. The respiration rate of the same activated sludge in the presence of 10, 100 and 1000 mg/L of test substance under otherwise identical conditions was also measured. The inhibitory effect of the test item at a particular concentration was expressed as a percentage difference from the mean respiration rates of the two controls. It was found that no significant inhibition of respiration was caused by the test substance.
Under the experimental conditions and based on nominal concentrations, the 3h-EC50 value was determined to be >1000 mg/L.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.