Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction

Test material

Constituent 1
Chemical structure
Reference substance name:
Haematoxylin
EC Number:
208-237-3
EC Name:
Haematoxylin
Cas Number:
517-28-2
Molecular formula:
C16H14O6
IUPAC Name:
haematoxylin

Results and discussion

Mass median aerodynamic diameter:
ca. 29.9 µm
Geometric standard deviation:
<=
Particle size
Key result
Percentile:
D10
Mean:
ca. 47.45 µm
St. dev.:
57.592
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
> 0 - < 2 µm
Distribution:
>= 0 - <= 0 %
No.:
#2
Size:
> 2 - < 200 µm
Distribution:
97.53 %
No.:
#3
Size:
>= 200 µm
Distribution:
>= 2.47 - <= 2.47 %

Applicant's summary and conclusion

Conclusions:
The particle size distribution of the test item HEMATOXYLIN HPL has been determined and the following results were obtained:
- 0 % of particles own a diameter under 2 μm.
- 97.53 % of particles own a diameter between 2 μm and 200 μm.
- 2.47 % of particles own a diameter over 200 μm.
Executive summary:

The particle size distribution of the test item HEMATOXYLIN HPL has been determined and the following results were obtained:

- 0 % of particles own a diameter under 2 μm.

- 97.53 % of particles own a diameter between 2 μm and 200 μm.

- 2.47 % of particles own a diameter over 200 μm.