Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test O.3 (Gravimetric test for oxidizing solids)
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Chloro[29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]aluminium
EC Number:
237-998-4
EC Name:
Chloro[29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]aluminium
Cas Number:
14154-42-8
Molecular formula:
C32H16AlClN8
IUPAC Name:
31h-phthalocyaninato(2-)-n29,n39,n31,n32]-chloro[29(sp-5-12)-aluminu; chloro[29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]-,(SP-5-12)-Aluminum;CHLOROALUMINUM PHTHALOCYANINE;CHLORO(29H,31H-PHTHALOCYANINATO)ALUMINUM; CHLORO(PHTHALOCYANINATO)ALUMINIUM;ALUMINUM PHTHALOCYANINE CHLORIDE;PHTHALOCYANINE CHLOROALUMINUM; chloro[29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]aluminium
Test material form:
solid: particulate/powder

Results and discussion

Test results (Oxidising solids)open allclose all
Key result
Sample tested:
reference: 3:7 mixture potassium bromate + cellulose
Parameter:
mean burning time
Result:
74.6 s
Key result
Sample tested:
1:1 sample-to-cellulose ratio
Parameter:
mean burning time
Result:
> 180 s
Key result
Sample tested:
4:1 sample-to-cellulose ratio
Parameter:
mean burning time
Result:
> 180 s

Applicant's summary and conclusion

Interpretation of results:
other: not classified
Conclusions:
Based on the results that the mean burning times of Tested-mixture Ⅰ and of Ⅱ were both greater than that of Standard-mixture Ⅰ, it can be ascertained that the sample is not a oxidizing solid.