Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26 April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC, 1995: The Collaborative International Pesticides Analytical Council Limited, England, CIPAC MT 12 "Flash Point (12.3 Pensky Martens Closed Tester)". In: CIPAC Handbook, Vol. F, "Physico-chemical Methods for Technical and Formulated Pesticides".
GLP compliance:
yes
Type of method:
closed cup
Remarks:
Pensky Martens Closed Tester Method.
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Test Item Name TYZOR ACtivate 422
IUPAC Name Citric acid, sodium titanium salt
C.A. Name Information not provided by Sponsor
CAS Number 68959-15-9
Batch/Lot Number 334-300179/000009
Analysed Purity (Provided by Sponsor) As Ti: 2.13% w/w (Refer Certificate of Analysis in APPENDIX 2)
Appearance Pale yellow clear liquid
Manufactured by Dorf Ketal Speciality Catalyst Private Limited
Supplied to JRF by Dorf Ketal Speciality Catalyst Private Limited
Date of Manufacture August 2016
Date of Expiry August 2018

Storage Condition (at JRF) As per the instruction received from the Sponsor on storage of the test item, the test was stored:
Storage Condition : Protected from light, air and moisture. Once opened container was kept under nitrogen blanket to prevent decomposition
Storage Container : In original container as supplied by thesponsor
Storage Location : Test Item Control Office, JRF
Key result
Flash point:
> 103 °C
Atm. press.:
ca. 760 mm Hg

The flash point of TYZOR ACtivate 422 was determined by the Pensky Martens Closed TesterMethod.

The flash point of TYZOR ACtivate 422 were > 103 °C (the test item began to boil at 103 °C) at normal atmospheric pressure (i.e. 760 mm Hg) in all the three replications.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of substance was observed by Pensky Martens Closed Tester Method and was found to be > 103 °C at normal atmospheric pressure i.e. 760 mm Hg.
Executive summary:

The flash point of substance was observed by Pensky Martens Closed Tester Method and was found to be > 103 °C at normal atmospheric pressure i.e. 760 mm Hg.

Description of key information

The flash point of substance was observed by Pensky Martens Closed Tester Method and was found to be > 103 °C at normal atmospheric pressure i.e. 760 mm Hg. The test item began to boil at 103 °C in all the three replications so reliable value could not be measured.

Key value for chemical safety assessment

Additional information