Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Isobutylbenzene
EC Number:
208-706-2
EC Name:
Isobutylbenzene
Cas Number:
538-93-2
Molecular formula:
C10H14
IUPAC Name:
(2-methylpropyl)benzene

Sampling and analysis

Analytical monitoring:
no

Test solutions

Vehicle:
no
Details on test solutions:
Application of the test substance: Direct addition by initial weight into the test flasks. The test substance was weighed in the required amounts for the test concentrations directly to the test vessels.

Test organisms

Test organisms (species):
activated sludge, domestic
Details on inoculum:
Source: municipal activated sludge; taken from the aeration tank of the wastewater treatment plant of Mannheim, Germany

Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h

Test conditions

Test temperature:
19.4 – 19.9 °C
pH:
7.4 (in the replicates, controls)
Dissolved oxygen:
Oxygen concentration during aeration: > 2 mg/L
Oxygen concentration immediately before measurement:> 7 mg/L
Nominal and measured concentrations:
Nominal: 0, 62.5, 125, 250, 500, 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: Glas-beakers (nominal volume 1L)
- Type (delete if not applicable): open
- Material, size, headspace, fill volume: Glass, 500 ml fill volumne
- Aeration: yes
- No. of vessels per concentration (replicates): 9
- No. of vessels per control (replicates): 6
- No. of vessels per abiotic control (replicates): 6
- Sludge concentration (weight of dry solids per volume): 1.5 g/L dw


TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: accrding to OECD 209

OTHER TEST CONDITIONS
- Adjustment of pH: yes, with 1 M sodium hydroxide to pH 7.2 (stock solution)
- Photoperiod: not relevant
- Light intensity: not relevant

EFFECT PARAMETERS MEASURED (with observation intervals if applicable) : oxygen consumption after 3 hrs.

TEST CONCENTRATIONS
- Spacing factor for test concentrations: 2
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol

Results and discussion

Effect concentrationsopen allclose all
Key result
Duration:
3 h
Dose descriptor:
EC10
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Results with reference substance (positive control):
EC50 of the positi9ve control 3,5-dichlorophenol was 6 mg/L
Reported statistics and error estimates:
The consumption rates were used for the determination of the ECx for the reference substance by the probit method based on Finney with the software TOXRAT Professional 2.10. The effect concentrations were given with an accuracy of 2 significant digits.

Applicant's summary and conclusion