Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25.06.2012 to 09.11.2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study according to GLP guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
methyl (2R)-2-amino-3-(1H-indol-3-yl)propanoate hydrochloride
EC Number:
639-469-7
Cas Number:
14907-27-8
Molecular formula:
C12H15ClN2O2
IUPAC Name:
methyl (2R)-2-amino-3-(1H-indol-3-yl)propanoate hydrochloride

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.

Any other information on results incl. tables

Result (diameter) d10 - d50 - d90 - dmean - Standard deviation

1st Measurement 7.084 µm - 33.99 µm - 121 .21 µm - 50.27 µm - 53.29 µm

2nd Measurement 7.063 µm - 33.31 µm - 125.1 µm - 51.47 µm - 58.59 µm

3rd Measurement 7.133 µm - 32.57 µm - 140.9 µm - 54.48 µm - 62.35 µm

Average: 7.09 µm - 33.3 µm - 129.1 µm - 52.07 µm - 58.1 µm

Standard deviation: 0.04 µm - 0.71 µm - 10.43 µm ----- -----

Applicant's summary and conclusion

Conclusions:
The particle size distribution (volume distribution) of the test item in an air stream was measured by Iaser diffraction.
The average of three measurements is: d10: 7.09 µm, d50: 33.3 µm, d90: 129.1 µm, d mean: 52 .07 µm