Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11th September 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: lot 05347/MA
Key result
Flash point:
> 350 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Executive summary:

The flash point was measured with Pensky Martens apparatus at > 350 °C.

Description of key information

Key value for chemical safety assessment

Additional information

FLP > 350 °C