Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Reference substance name:
Hydrocarbons from mixed waste plastics, thermo-mechanical depolymerization condensate
EC Number:
948-892-9
Molecular formula:
C5-C29
IUPAC Name:
Hydrocarbons from mixed waste plastics, thermo-mechanical depolymerization condensate
Test material form:
liquid
Details on test material:
Hydrocarbons from mixed waste plastics, thermo-mechanical depolymerization condensate. It is a complex combination of hydrocarbons as described in section one.

Results and discussion

Flash point
Key result
Flash point:
< 40 °C
Atm. press.:
ca. 101.3 kPa

Applicant's summary and conclusion

Interpretation of results:
Category 1 (extremely flammable liquids) based on GHS criteria
Conclusions:
The flashpoint of the substance using international standard method D93 was found to be less than 40 C.
Executive summary:

The flashpoint of the substance using international standard method D93 was found to be less than 40 C. It corresponds to category 1 of GHS criteria because the initial boiling point is less than 35 C.