Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Oct 2017 - Mar 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Version / remarks:
1981
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D50
Mean:
7 µm
St. dev.:
0.05
Percentile:
D10
Mean:
1.7 µm
St. dev.:
0
Percentile:
D90
Mean:
15.3 µm
St. dev.:
0.05
Conclusions:
The test item has a mean particle size D50 = 7 µm, which was determined by laser diffraction measurement.
Executive summary:

The test item has a mean particle size D50 = 7 µm, which was determined by laser diffraction measurement according to OECD guideline 110 and ISO 13320 under GLP conditions.

Description of key information

The test item has a mean particle size D50 = 7 µm, which was determined by laser diffraction measurement according to OECD guideline 110 and ISO 13320 under GLP conditions.

Additional information