Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Internal procedure 4163-340 can be considered similar to OECD guideline 109.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Principles of method if other than guideline:
A weghted quantity of the substance is introduced in a pycnometer. Weight of the sample is recorded and compared to water weight for the same volume.
GLP compliance:
no
Type of method:
pycnometer method
Remarks:
similar to

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Dynamic viscosity of test material:
256 P at 25°C

Results and discussion

Density
Type:
relative density
Density:
1.2 other: no unit
Temp.:
25 °C

Applicant's summary and conclusion

Conclusions:
The specific gravity of the test item is 1.20 at 25°C.