Endpoint:
auto-ignition temperature (liquids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid non flammable in air, e.g. no flash point up to 200°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-08-04 (experimental phase)
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
in-house data with poorer documentation, but given data allows to conclude that the study was properly conducted
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not applicable
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
Pensky-Martens closed cup according DIN EN ISO 2719, Method A
Deviations:
not specified
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
201.5 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Remarks:
EU implementation
Conclusions:
The study was performed according to DIN EN ISO 2719 with the Pensky-Martens closed cup method on the substance to be registered itself, the test procedure is sufficiently documented and therefore reliability of Klimisch 2 has been assigned. The flash point was determined to be 201.5°C at 101.3 kPa. Hence, it does not need to be regarded as flammable liquid according to Regulation 1272/2008, as it defines flammable liquid as a liquid having a flash point of not more than 60°C.
Executive summary:

The flash point was determined according to DIN EN ISO 2719 with the Pensky-Martens closed cup method to be 201.5°C at 101.3 kPa. The substance is not a flammable liquid according to Regulation 1272/2008.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion