Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 Oct 2017 to 01 Nov 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester (Eralytics, Vienna, Asutria)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor and ZMG-197685
- Expiration date of the lot/batch: 09 December 2017
- Purity test date: 28 December 2016
Key result
Flash point:
85 °C
Atm. press.:
ca. 1 atm

The results of the main study on the determination of the flash-point of the test item are given in Table 5.

The difference between the results obtained with the Test 1 and Test 2 was≤2°C. From this, it was concluded that the flash-point of the test item is the lowest flash-point obtained.

Table 5          
Main Study: Flash-point of the Test Item

Test

Flash-point

[°C]

Lowest flash-point

[°C]

1

85

85

2

87

 

Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The closed cup method was applied for the determination of the flash-point of 1,3-dichloro-2-propanol.
The flash-point of the test item was 85°C.

Description of key information

The closed cup method was applied for the determination of the flash-point of 1,3-dichloro-2-propanol.

The flash-point of the test item was 85°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
85 °C

Additional information