Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jan 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2003
Qualifier:
according to guideline
Guideline:
other: Recommendations on the TRANSPORT OF DANGEROUS GOODS: Manual of Tests and Criteria: Class 3, Flammable Liquids
Version / remarks:
6th edition, New York and Geneva, 2015
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
142.5 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The test item has a flash point of 142.5 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2003).
Executive summary:

The test item has a flash point of 142.5 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2003).

Description of key information

The test item has a flash point of 142.5 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2003).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
142.5 °C

Additional information

The test item has a flash point of 142.5 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2003).

According to the results of the test on the flash point, the test item is classified as following:

UN Transport Regulation: With a measured flash point > 60 °C, the test item does not have to be classified as flammable liquid in class 3 according to the UN Transport Regulation.

GHS (CLP Regulation EC 1272/2008 Annex 1: 2.6): With a measured flash point > 60 °C, the test item does not have to be classified as flammable liquid according to GHS or CLP Regulation EC 1272/2008 Annex 1.