Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-09-13 to 2018-01-31
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) - Method B: Fibre Length and Diameter Distributions
Version / remarks:
January 21, 1998
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Remarks on result:
not measured/tested
Key result
Percentile:
D10
Mean:
8.1 µm
Remarks on result:
other: Standard deviation was not determined.
Key result
Percentile:
D50
Mean:
22.4 µm
Remarks on result:
other: Standard deviation was not determined
Key result
Percentile:
D90
Mean:
37.3 µm
Remarks on result:
other: Standard deviation was not determined
Conclusions:
The test item Tetrahydrofolic acid has a median particle size D50 = 22 µm, which was determined by laser diffraction measurement, according to ISO 13320 and OECD 110.

Description of key information

Particle size distribution: D50 = 22.4 µm (OECD 110, GLP)

Additional information

The test item Tetrahydrofolic acid has a median particle size D50 = 22 µm, which was determined by laser diffraction measurement, according to ISO 13320 and OECD 110.