Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
no
Type of method:
dynamic method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
< 1 Pa
Remarks on result:
other: 0.008 by Antoine's law
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
< 1 Pa
Remarks on result:
other: 0.014 by Antoine's law

Applicant's summary and conclusion

Conclusions:
Vapour pressure is determined according to A4 EU method. The study reports a vapour pressure of 0.008 Pa at 20°C and 0.014 Pa at 25°C
Executive summary:

Vapour pressure is determined according to A4 EU method. The study reports a vapour pressure of 0.008 Pa at 20°C and 0.014 Pa at 25°C