Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 October 2017- 01 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ of 2002
GLP compliance:
yes (incl. QA statement)
Type of method:
cascade impaction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
2-hydroxy-N-1H-1,2,4-triazol-3-ylbenzamide
EC Number:
253-021-4
EC Name:
2-hydroxy-N-1H-1,2,4-triazol-3-ylbenzamide
Cas Number:
36411-52-6
Molecular formula:
C9H8N4O2
IUPAC Name:
2-hydroxy-N-1H-1,2,4-triazol-3-ylbenzamide
Test material form:
solid: particulate/powder
Details on test material:
Batch:102Z5
Purity: 99.9%
white powder

Results and discussion

Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
< 100 µm
Distribution:
ca. 96.3 %
No.:
#2
Size:
< 10 µm
Distribution:
ca. 1.07 %
No.:
#3
Size:
< 5.5 µm
Distribution:
ca. 0.101 %

Applicant's summary and conclusion

Conclusions:
Particle size data acquired for the test item:

Percentage of test item with an inhalable particle size <100 μm, (Method: Sieve), 96.3%
Percentage of test item with a thoracic particle size <10.0 μm, (Method: Cascade Impactor), 1.07%
Percentage of test item with a respirable particle size <5.5 μm, (Method: Cascade Impactor), 0.101%