Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was performed according to guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Details on test material:
- Lot/batch No.: CM71217681
- Storage condition of test material: room temperature in the dark

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
394 °C
Atm. press.:
>= 102.4 - <= 102.8 kPa
Remarks on result:
other:

Any other information on results incl. tables

Table 1: Augto-Ignition Study

Test Temperature 0C

Test Volume (uL)

Ignition Delay (sec)

Observations

50 (clean tube)

70

> 300

No ignition

100 (clean tube)

70

> 300

No ignition

150 (clean tube)

70

> 300

No ignition

200

70

> 300

No ignition, grey fumes emitted

250

70

> 300

No ignition, grey fumes emitted

300

70

> 300

No ignition, grey fumes emitted

350

70

> 300

No ignition, grey fumes emitted

400 (clean tube)

70

> 300

No ignition, grey fumes emitted

400 (clean tube)

200

> 300

No ignition, grey fumes emitted

400 (clean tube)

400

18

Orange flame, grey fumes emitted

390

400

> 300

No ignition, grey fumes emitted

394

400

> 300

No ignition, grey fumes emitted

396

400

> 300

No ignition, grey fumes emitted

398 (clean tube)

400

15

Orange flame, grey fumes emitted

396 (clean tube)

400

300

No ignition, grey fumes emitted

396 (clean tube)

600

17

Orange flame, grey fumes emitted

394 (clean tube)

600

> 300

No ignition, grey fumes emitted

394 (clean tube)

800

16

Orange flame, grey fumes emitted

392 (clean tube)

800

> 300

No ignition, grey fumes emitted

392 (clean tube)

1000

> 300

No ignition, grey fumes emitted

392 (clean tube)

1200

> 300

No ignition, grey fumes emitted

392 (clean tube)

1400

> 300

No ignition, grey fumes emitted

392 (clean tube)

1600

> 300

No ignition, grey fumes emitted

Applicant's summary and conclusion

Conclusions:
The auto-ignition temperature of the test substance is 394 deg. C
Executive summary:

The auto-ignition temperature of the test substance was determined according to EU method A15. The auto-ignition temperature of the test substance is 394 degrees C (measured between pressures of 102.4 - 102.8 kPa.