First-aid measures

Description of first aid measures General information: Immediately remove any clothing soiled by the product.

After inhalation: Supply fresh air; consult doctor in case of complaints.

After skin contact: Immediately wash with water and soap and rinse thoroughly.

After eye contact: Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

After swallowing: If symptoms persist consult doctor.

Eyes: Dust may irritate eyes mechanically.

Possible routes of intake: Intake by swallowing or inhalation of dust.

Fire-fighting measures

Extinguishing media Suitable extinguishing agents: CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. For safety reasons unsuitable extinguishing agents: No restriction in large fires.

Special hazards arising from the substance or mixture: The possibility of formation of explosive dust/air mixtures under certain conditions should be basically considered during handling and processing.

In case of fire, the following can be released:

Carbon monoxide (CO)

Nitrogen oxides (NOx)

Hydrogen chloride (HCl)

Advice for firefighters Protective equipment: Wear self-contained respiratory protective device.

Chemical resistant protective suit.

Under the protective suit a fire protective suit according to EN 469 should be applied.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Wear protective clothing.

Use respiratory protective device against the effects of fumes/dust/ aerosol.

Avoid formation of dust.

Environmental precautions: Keep contaminated washing water and dispose of appropriately.

Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

Methods and material for containment and cleaning up: Pick up mechanically. If formation of dust cannot be avoided use respiratory filter device.

Handling and storage

Precautions for safe handling: Any unavoidable deposit of dust must be completely removed. Fill only in dedicated and assigned containers.

Keep containers tightly sealed.

Conditions for safe storage, including any incompatibilities:

Storage: Requirements to be met by storerooms and receptacles: Store in a dry location, keep away from humidity.

Store in a cool location.

Information about storage in one common storage facility: Store away from oxidising agents.

Further information about storage conditions: Protect from heat and direct sunlight.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not classified as dangerous for transport.
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not classified as dangerous for transport.
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not classified as dangerous for transport.
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not classified as dangerous for transport.
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Additional information about design of technical facilities: Take care of sufficient ventilation. Avoid formation of dust.

Exposure controls: This product is exclusively dedicated for the application as isolated and transported intermediate under strictly controlled conditions according to Article 18 of Regulation EC 1907/2006 (REACH-Regulation).

Please note: This safety data sheet corresponds to the specific conditions which justify the registration according to Art. 18 of Regulation (EC) 1907/2006.

Personal protective equipment:General protective and hygienic measures: The usual precautionary measures are to be adhered to when handling chemicals.

Respiratory protection: Particle fi lter. The fi lter grade (P1 - P3) has to be established depending on work-place related limit values and the actual exposition.

Protection of hands: Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation.

For the permanent contact gloves made of the following materials are suitable: The following materials are known from experience to be suitable for protection against undissolved solids: rubber.

Check for tightness before use. Replace damaged gloves.

Eye protection: Safety glasses

Body protection: Necessary protective suit has to be selected individually based on risk assessment.

Limitation and supervision of exposure into the environment: Avoid spillage of product into the environment.

If possible use this material only in closed systems and devices. In case of open plant systems (sampling devices, filling and discharging,

cleansing works etc.) use local exhaust and collecting trays. Follow emission limit values. Measures in case of unwanted emissions should be established.

General protective and hygienic measures have to be observed. Employees who use this material/formulation must be trained and

demonstrably instructed about possible risks for man and environment.

Measures for prevention of hazards in case of unwanted leakage shall be implemented.

Stability and reactivity

Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.

Possibility of hazardous reactions: The possibility of formation of explosive dust/air mixtures under certain conditions should be principally considered during handling and processing.

Conditions to avoid: Temperatures > 40°C

Incompatible materials: Strong oxidizing agents.

Hazardous decomposition products: Nitrogen oxides

Hydrogen chloride (HCl)

Carbon monoxide and carbon dioxide

Disposal considerations

Waste treatment methods Recommendation: Must be specially treated adhering to official regulations.

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

If possible recovery or recycling.

Uncleaned packaging Recommendation: Empty contaminated packagings thoroughly. They may be recycled after thorough and proper cleaning.

Packagings that may not be cleansed are to be disposed of in the same manner as the product.

Appropriate disposal: Emptied and cleaned containers should be recycled.

Biological waste water treatment: Discharge into waste water channels and biological treatment plants only after clearence with the operating company and in accordance with local Authority approval.