Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 August 2017 to April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Council Regulation 440/2008, 30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
1,2,3-tris(2-octyldodecyl) 2-hydroxypropane-1,2,3-tricarboxylate
EC Number:
603-121-2
Cas Number:
126121-35-5
Molecular formula:
C66H128O7
IUPAC Name:
1,2,3-tris(2-octyldodecyl) 2-hydroxypropane-1,2,3-tricarboxylate
Test material form:
liquid
Details on test material:
Tris(octyldodecyl) citrate 99.87 %
Bis(octyldodecyl) citrate 0.13 %
Specific details on test material used for the study:
The test substance, 2,3-Propanetricarboxylic acid, 2-hydroxy-1,2,3-tris(2-octyldodecyl) ester was allocated the code ESTS 69/17 for reference throughout the study.
Name: 2,3-Propanetricarboxylic acid, 2-hydroxy-1,2,3-tris(2-octyldodecyl) ester (Citmol 320)
Physical state: Clear, faintly yellow liquid
Purity: 99.39%
Molecular weight: 1033.74 g/mol
Storage conditions: Room temperature (15 to 30°C)

Results and discussion

Flash point
Key result
Flash point:
> 110 °C
Atm. press.:
ca. 96.9 kPa

Any other information on results incl. tables

The certified calibration standard gave a flash point of 74.1°C corrected for atmospheric pressure, which was within the specification. No flash point was observed up to a mean corrected temperature of 111.1°C. Therefore the flash point of the test substanceis >110°C.The atmospheric pressure measured during testing was 96.9kPa.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test substance was found to be >110 °C at 96.9 kPa, under the conditions of the test.
Executive summary:

In this guideline (EU A.9) study, [conducted with GLP certification], the flash point of the test substance was found to be >110 °C at 96.9 kPa.