Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17.01.2018 - 06.02.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
GLP compliance:
not specified
Other quality assurance:
other: UNI EN ISO 9001:2015
Remarks:
Chemical, technological, sanitary and eco-toxicological analyses. Technical and scientific services, consulting and design of materials for biomedical and technological manufacturing fields (IAF 34)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 20170710
- Expiration date of the lot/batch: not specified
- Purity test date: not specified

RADIOLABELLING INFORMATION (if applicable)
not applicable


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: 4°C
- Stability under test conditions: not specified
- Solubility and stability of the test substance in the solvent/vehicle: not specified
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: not relevant

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: not specified
- Preliminary purification step (if any): not relevant
- Final dilution of a dissolved solid, stock liquid or gel: not relevant
- Final preparation of a solid: not relevant

FORM AS APPLIED IN THE TEST (if different from that of starting material): not relevant

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)
not applicable

OTHER SPECIFICS: not specified
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
< 0
Remarks on result:
other: the result was -0.47
Conclusions:
The partition coefficient octanol/water (log Pow) was equal to - 0.47.

Description of key information

The partition coefficient octanol/water (log Pow) was equal to - 0.47.

Key value for chemical safety assessment

Log Kow (Log Pow):
-0.47

Additional information