Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 25, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified
Type of method:
equilibrium method closed cup
Remarks:
Rapid equilibrium method in closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Remarks on result:
no flash point according to standard method
Remarks:
no flash point up to 300^C
Interpretation of results:
GHS criteria not met
Conclusions:
The test item Di-PETMP has no flash point up to 300 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003).
Executive summary:

The test item Di-PETMP has no flash point up to 300 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003).

Description of key information

The test item Di-PETMP has no flash point up to 300 °C.

Key value for chemical safety assessment

Additional information