Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
other: CIPAC MT 170
GLP compliance:
yes (incl. certificate)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Mitsubishi-Kagaku Foods Corporation, 6912911B
- Expiration date of the lot/batch: September 11, 2018
- Purity test date: October 14, 2016

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: 1-10 degrees C in darkness
Key result
Percentile:
D10
Mean:
125 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
Standard deviation was not given.
Key result
Percentile:
D90
Mean:
5 000 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
Standard deviation was not given.
No.:
#1
Size:
>= 7 100 µm
Distribution:
0.05 %
No.:
#2
Size:
>= 5 000 - < 7 100 µm
Distribution:
1.31 %
No.:
#3
Size:
>= 3 350 - < 5 000 µm
Distribution:
11.06 %
No.:
#4
Size:
>= 2 000 - < 3 350 µm
Distribution:
20.73 %
No.:
#5
Size:
>= 1 000 - < 2 000 µm
Distribution:
26.43 %
No.:
#6
Size:
>= 500 - < 1 000 µm
Distribution:
16.6 %
No.:
#7
Size:
>= 250 - < 500 µm
Distribution:
9.6 %
No.:
#8
Size:
>= 125 - < 250 µm
Distribution:
7.29 %
No.:
#9
Size:
>= 100 - < 125 µm
Distribution:
1.71 %
No.:
#10
Size:
>= 75 - < 100 µm
Distribution:
3.25 %

0.44% of material was retained on the pan.

Conclusions:
The particle size was range was determined to be between 125 (Rx >= 90%) and 5000 (Rx =< 10%) um.
Executive summary:

The particle size range was determined using the sieving method. The particle size was range was determined to be between 125 (Rx >= 90%) and 5000 (Rx =<10%) um.

Description of key information

The particle size range was determined using the sieving method. The particle size was range was determined to be between 125 (Rx >= 90%) and 5000 (Rx =<10%) um.

Additional information