Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with testing method ASTM D 7042 however not under GLP.
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
other: ASTM D 7042
Deviations:
no
GLP compliance:
no
Remarks:
Not specified
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
16.75
Conclusions:
The viscosity measured using the ASTM D 7042 method is 16.75 mm2/s at 20°C.
Executive summary:

The viscosity of the substance Hydrocarbons, C14-C19, isoalkanes, cyclics, <2% aromatics, measured using the ASTM D 7042 method, is 16.75 mm2/s at 20°C.

Endpoint:
viscosity
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with testing method ASTM D 445 however not under GLP.
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
other: ASTM D 445
Deviations:
no
GLP compliance:
no
Remarks:
Not specified
Type of method:
capillary viscometer (static)
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
7.68
Conclusions:
The viscosity measured using the ASTM D 445 method is 7.68 mm2/s at 40°C.
Executive summary:

The viscosity of the substance Hydrocarbons, C14-C19, isoalkanes, cyclics, <2% aromatics, measured using the ASTM D 445 method, is 7.68 mm2/s at 40°C.

Description of key information

There is no data available for Hydrocarbons, C13-C16, isoalkanes, <2% aromatics. Data is available for Hydrocarbons C14-C19, isoalkanes, cyclics, <2% aromatics and based on an analogue approach, this data is used for read across to Hydrocarbons, C13-C16, isoalkanes, <2% aromatics.

The viscosity of the substance Hydrocarbons, C14-C19, isoalkanes, cyclics, <2% aromatics measured using the ASTM D 7042 method is between 5.0 to 25.0 mm2/s at 20°C.

The viscosity of the substance Hydrocarbons, C14-C19, isoalkanes, cyclics, <2% aromatics, measured using the ASTM D 445 method, ranges from <7.0 to 9.0 mm2/s at 40°C.

Key value for chemical safety assessment

Additional information