Registration Dossier

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 301 D (Ready Biodegradability: Closed Bottle Test)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
natural water: freshwater
Details on inoculum:
River water
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
2 mg/L
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
45
Sampling time:
28 d

Applicant's summary and conclusion

Conclusions:
At 28-days the biodegradation was determined to be 45%.
Executive summary: