Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Approximately 100g of sample was heated in a conical flask with the heat source provided from a hot plate. A condenser was used to collect any distillate from the substance, with a thermometer measuring the temperature of the test substance, and a second thermometer to monitor the condensate temperature. The sample was heated through a range of 100ºC to 230ºC, with the temperature of the condensate monitored throughout.
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 230 °C
Atm. press.:
1 atm
Remarks on result:
not determinable because of methodological limitations
Remarks:
Test material decomposed prior to auto-ignition.

Applicant's summary and conclusion

Conclusions:
The sample was not observed to ignite during the test, therefore it can be concluded that the autoflammability temperature of [(3-Oxo-butyryl)-phenyl-amino]-acetic acid ethyl ester is greater than 230ºC.
Executive summary: