Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Product no. B4429, Lot no. SLBK5235V
- Expiration date of the lot/batch: 30 April 2018
- Purity test date: na

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: no

Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
0 s
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The flammability of the substance was determined in an experimental study under GLP conditions according to EU Methods A.10.

The test substance did not ignite for 2 minutes. Therefore, the main test was not carried out.

The test substance is not classified as flammable according to EC 1272/2008 (CLP) Annex 1: 2.7.

Interpretation of results:
not classified based on GHS criteria
Executive summary:

The flammability of the substance was determined in an experimental study under GLP conditions according to EU Methods A.10.

The test substance did not ignite for 2 minutes. Therefore, the main test was not carried out.

The test substance is not classified as flammable according to EC 1272/2008 (CLP) Annex 1: 2.7.

Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Interpretation of results:
not classified based on GHS criteria
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Interpretation of results:
not classified based on GHS criteria

Description of key information

The flammability of the substance was determined in an experimental study under GLP conditions according to EU Methods A.10 (SIA97).

The test substance did not ignite for 2 minutes. Therefore, the main test was not carried out.

The test substance is not classified as flammable according to EC 1272/2008 (CLP) Annex 1: 2.7.

In addition, based on handling experience, the test substance is regarded as not being flammable in contact with water and as not pyrophoric.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The flammability of the substance was determined in an experimental study under GLP conditions according to EU Methods A.10.

The test substance did not ignite for 2 minutes. Therefore, the main test was not carried out.

The test substance is not classified as flammable according to EC 1272/2008 (CLP) Annex 1: 2.7.

In addition, based on handling experience, the test substance is regarded as not being flammable in contact with water and as not pyrophoric.