Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10-2017
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
no
Type of method:
dynamic method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Vapour pressureopen allclose all
Key result
Temp.:
20 °C
Vapour pressure:
50 Pa
Key result
Temp.:
25 °C
Vapour pressure:
67 Pa
Key result
Temp.:
50 °C
Vapour pressure:
249 Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of MIRAMER M1086 was 50 Pa at 20°C, 67 Pa at 25°C and 249 Pa at 50°C (calculated by extrapolation of the measured vapour pressure curve). Reaction and/or decomposition of the test material was not observed during the test.
Executive summary:

The vapour pressure of MIRAMER M1086 was 50 Pa at 20°C, 67 Pa at 25°C and 249 Pa at 50°C.