Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Principles of method if other than guideline:
Laser diffraction method according to ISO 13320
GLP compliance:
yes (incl. QA statement)
Type of method:
determination of fibre length and diameter distributions
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Anthranilamide
EC Number:
201-851-2
EC Name:
Anthranilamide
Cas Number:
88-68-6
Molecular formula:
C7H8N2O
IUPAC Name:
2-aminobenzamide
Test material form:
other: solid
Details on test material:
Name of test material (as cited in study report): "Anthranilamide", 2-aminobenzamide
Analytical purity: 99.2 g/100 g; area% of HPLC corrected by water (0.3 g/100 g) and sodium content (0.5 g/100 g) as determined in study 15L00067 of Competence Center Analytics
Lot/batch No.: 15/0042-1
Storage condition of test material: Ambient temperature

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
44 µm
St. dev.:
0.41
Remarks on result:
other: Standard Deviation calcualted separately from the report.
Key result
Percentile:
D50
Mean:
140 µm
St. dev.:
5.7
Remarks on result:
other: Standard Deviation calcualted separately from the report.
Key result
Percentile:
D90
Mean:
507 µm
St. dev.:
2.1
Remarks on result:
other: Standard Deviation calcualted separately from the report.
Key result
Percentile:
other: D[3,2]
Mean:
91 µm
St. dev.:
2.8
Remarks on result:
other: Standard Deviation calcualted separately from the report.
Key result
Percentile:
other: D[4,3]
Mean:
216 µm
St. dev.:
3.5
Remarks on result:
other: Standard Deviation calcualted separately from the report.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
< 4 µm
Distribution:
0 other: vol%
No.:
#2
Size:
< 10 µm
Distribution:
0.44 other: vol%
No.:
#3
Size:
< 100 µm
Distribution:
36.67 other: vol%

Any other information on results incl. tables

Results:   

measurement

d(0.1)

[μm]

d(0.5)

[μm]

d(0.9)

[μm]

D[3,2]

[μm]

D[4,3]

[μm]

1

43

136

506

89

213

2

45

144

509

93

218

mean*

44

140

507

91

216

 

measurement

<4 μm

[vol%]

<10 μm

[vol%]

<100 μm

[vol%]

1

0.00

0.47

37.65

2

0.00

0.41

35.68

mean*

0.00

0.44

36.67

*) Using all single measuring points from the measurements 1 and 2, a new distribution was calculated, giving the mean values for each parameter.

D[3,2): mean by surface (Sauter)

D[4,3): mean by volume (De Brouker)

Applicant's summary and conclusion