Description of first aid measures:
Pay attention to self-protection.
Remove victims from hazardous area. Immediately remove soiled or soaked clothing and remove it to a safe distance. Keep victim warm, in a stabilized position and covered.
Do not leave victims unattended.
If the casualty is unconscious: Place the victim in the recovery position.

Inhalation:
Inhalation is possible if aerosols, mists, dusts, or smoke form.
Move victims into fresh air.
With labored breathing: Provide with oxygen. Consult a doctor.
If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact:
Wash off affected area immediately with plenty of water for at least 15 minutes.
If symptoms persist, consult a physician for treatment.

Eye contact:
With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.
In case of persistent discomfort: Consult an ophthalmologist.

Ingestion:
Rinse mouth.
Immediately give large quantities of water to drink.
Obtain medical attention.

Most important symptoms and effects, both acute and delayed:
Symptoms: None known
Hazards: Other dangerous properties can not be excluded.

Indication of any immediate medical attention and special treatment needed:
This product has not been completely analyzed yet and all health hazards might not be known.

Fire-fighting measures

Extinguishing media:
Suitable extinguishing media: All extinguishing substances suitable.
Unsuitable extinguishing media: Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:
May be released in case of fire: organic, nitrogenous and sulphurous products of decomposition, carbon monoxide, nitric oxides, sulphur dioxide.
Carbon dioxide (CO2)

Advice for firefighters:
Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.
Water used to extinguish fire should not enter drainage systems, soil or stretches of water.
In case of fire, remove the endangered containers and bring to a safe place, if this can be done safely.
Use water spray to cool unopened containers.
Fire residues should be disposed of in accordance with the regulations.
Pay attention to self-protection.
Keep out unprotected persons.
In case of fire: full protective suit and wear a self contained respiratory apparatus.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Keep unauthorized persons away.

Environmental precautions:
Observe regulations on prevention of water pollution (check, dam up, cover up).
Do not allow entrance in sewage water, soil, stretches of water, drainage systems, surface water.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:
Pack and label wastes like the pure substance. Do not detach label from the delivery containers prior to disposal.
Disposal according to local authority regulations.

Reference to other sections:
Wear personal protective equipment; see Exposure controls/personal protection.

Handling and storage

Precautions for safe handling:
Use permissible in closed systems only. Handle and transfer product in closed systems only (gas displacement device).
Ensure that apparatus and pipelines are free from leaks. Do not ventilate into the open.
Suitable loading and unloading device required.

Conditions for safe storage, including any incompatibilities:
Advice on protection against fire and explosion:
Normal measures for preventive fire protection.
Ensure there are sufficient retaining facilities for water used to extinguish fire.
Further information: VDI 2263 "Dust fires and dust explosions; dangers, evaluation, preventive measures."
Storage:
Store in the original receptacle, keeping this tightly sealed, under cool and dry conditions.
Keep at temperatures of between 2 °C and 8 °C.
Observe prohibition against storing together!
Further information:
Protect from sunlight, warmth and heat.
In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.

German storage class
4.2 - Pyrophoric and self-heating hazardous materials

Transport information

Land transport (ADR/RID)

UN number:
2930
Shippingopen allclose all
Class:
6.1
Classification code:
TF3
Packaging group:
I
Labels:
6.1 (4.1)
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
2930
Shippingopen allclose all
Class:
6.1
Classification code:
TF3
Packaging group:
I
Labels:
6.1 (4.1)
Remarksopen allclose all

Marine transport (IMDG)

UN number:
2930
Proper shipping name and description:
TOXIC SOLID, FLAMMABLE, ORGANIC, N.O.S. (cyclopropyl[4-(phenylmethyl)-1-piperazinyl]methanone hydrochloride)
Chemical name:
cyclopropyl[4-(phenylmethyl)-1-piperazinyl]methanone hydrochloride
Class:
6.1 (4.1)
Packaging group:
I
EmS code:
F-A, S-G
Labels:
6.1, 4.1
Marine pollutant
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
2930
Proper shipping name and description:
Toxic solid, flammable, organic, n.o.s. (cyclopropyl[4-(phenylmethyl)-1-piperazinyl]methanone hydrochloride)
Chemical name:
cyclopropyl[4-(phenylmethyl)-1-piperazinyl]methanone hydrochloride
Class:
6.1 (4.1)
Packaging group:
I
Labels:
6.1, 4.1
Remarksopen allclose all

Additional transport information

Additional transport information
Loading instructions/Remarks
IATA_C: ERG-Code 6F
IATA_P: ERG-Code 6F
Keep separate from foodstuffs, luxury foods, feedstuffs

Combination traffic :
Labelling of containers / shipping units following main product run as per sea or air transport regulations.

Exposure controls / personal protection

Control parameters:
Other information:
Contains no substances with occupational exposure limit values.

DNEL/DMEL values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

PNEC values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

Exposure controls:

Engineering measures:
Provide for installation of emergency shower and eye bath.
Refill and handle product only in closed system.
Leak detection recommended
Do not add wastewater to a biological wastewater treatment plant
Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
All precautionary measures indicated have to be observed.

Exposure controls:
The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.

Personal protective equipment:

Respiratory protection:
Full mask, particle filter P3, colour code: white
Accidental release measures
In the case of respirable dust, use self-contained breathing apparatus.
Note time limit for wearing respiratory protective equipment.

Hand protection:
Glove material: Nitrile, for example, Dermatril 740, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness: 0.11 mm
Method: DIN EN 374
Accidental release measures:
Glove material: Nitrile/Chloroprene, for example, Nitopren 717, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness. 0.65 mm
Method: DIN EN 374
Selection of protective gloves to meet the requirements of specific workplaces.
Suitability for specific workplaces should be clarified with protective glove manufacturers.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Remember that the useful time per day of a chemical protection glove may be much shorter than the permeation time determined according to EN 374 due to the many different influential factors involved (e.g. temperature).

Eye protection:
Safety glasses with side-shields conforming to EN166
Accidental release measures: close-fitting protective goggles (e.g. closed goggles)

Skin and body protection:
Select materials and equipment for physical protection depending on the concentration and volume of hazardous substances and the workplace involved.

Hygiene measures:
Remove and wash contaminated clothing before re-use.
Do not eat, drink, smoke, or sniff while at work. Wash your hands and/or face before breaks and before termination of work.
Preventive skin protection is recommended.
Use barrier cream regularly.

Protective measures:
All precautionary measures indicated have to be observed.
Risk assessment and risk monitoring of all work places required.
Health, Safety and Emergency Management System recommended.
Regular safety training is a must.
Written approval necessary in case of non-routine jobs, e.g. maintenance activities.
The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).
It should be defined in the work place in the form of a risk analysis according to directive 89/686/EEC and amendments.

Environmental exposure controls:
In some cases, exhaust air scrubbers, filters or technical changes to the processing plant will be required in order to decrease emissions to acceptable values.

Stability and reactivity

Reactivity:
No further information available

Chemical stability:
No further information available

Possibility of hazardous reactions:
No further information available

Conditions to avoid:
No further information available

Incompatible materials:
No further information available

Hazardous decomposition products:
No further information available

Disposal considerations

Waste treatment methods:

Product:
Disposal according to local authority regulations.
Pack and label wastes like the pure substance. Do not detach label from the delivery containers prior to disposal.
Strictly controlled conditions during disposal or treatment to air, wastewater and waste.
Do not add wastewater to a biological wastewater treatment plant

Uncleaned packaging:
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.

Waste Key Number:
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.