Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 20 May 2016 and 01 June 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor Lot/Batch number 5399561P10
- Expiration date of the lot/batch: 25 January 2020

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature in the dark
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
> 2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The test item melted and failed to ignite during the 2 minutes that the Bunsen flame was applied.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item melted and failed to ignite during the 2 minutes that the Bunsen flame was applied.

The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.

Not highly flammable, using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The flammability (solids) was determined by measuring the burning rate of test item prepared as a pile of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

The pile failed to ignite during the 2 minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.

Justification for classification or non-classification

Substance is not highly flammable in Test A10 (flammability solids)