Registration Dossier

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: well performes study according nto achnowledged standard

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: VDI 2263 sheet 1
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Burning time:
0 s
Remarks on result:
other: The product showed no reaction when an ignition source (flame or hot wire) was applied at ambient temperature.
Remarks:
BZ1 (no ignition)

Applicant's summary and conclusion

Interpretation of results:
non flammable
Conclusions:
Combustion Number 1 can be assigned to the substance (no ignition)

UN transport regulation: The substance does not have to be classified as a “readily combustible solid”, class 4.1, of the transport regulations.
EU-GHS/CLP: The substance does not have to be classified as a “flammable solid”.
Regulation (EG) 440/2008 (test methods for REACH): The substance does not have to be classified as a “highly flammable solid”.
Executive summary:

The substance was tested for flammability according to VDI 2263 sheet 1.

The product showed no reaction when an ignition source (flame or hot wire) was applied at ambient temperature. A propagation of the combustion was not observed. The product melted.

The combustion behaviour of the product at ambient temperature is characterized by the burning index BZ 1 (no ignition).

Due to the fact that no propagation of the combustion was observed the burning rate had not to be determined.