Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1997

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 92/69/EEC, A.4 Vapour Pressure Balance
GLP compliance:
yes
Type of method:
other: Vapour pressure balance method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Test no.:
#1
Temp.:
ca. 40 °C
Vapour pressure:
ca. 1.06 Pa
Remarks on result:
other: First vapour pressure
Test no.:
#2
Temp.:
ca. 35 °C
Vapour pressure:
ca. 0.3 Pa
Remarks on result:
other: Second vapour pressure
Test no.:
#3
Temp.:
ca. 25 °C
Vapour pressure:
ca. 0.3 Pa
Remarks on result:
other: Estimated vapour pressure value.

Applicant's summary and conclusion