Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes (incl. certificate)
Type of method:
thermal analysis

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): Cyanethylimidazol
Analytical purity: 89,4 area% by GC (see BSF GLP Study 11L00264)
Lot/batch No.: 000STD77L0 out of C1310, 2011-04-08

Results and discussion

Melting / freezing point
Melting / freezing pt.:
-79 °C
Atm. press.:
1 013.25 hPa
Remarks on result:
other: glass transition

Any other information on results incl. tables

No melting temperature was found between -100°C and room temperature.

The test item is liquid at room temperature.

A glass transition was found at -79°C.

Applicant's summary and conclusion