Registration Dossier

Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 May 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The pH was measured with a calibrated pH meter.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
no guideline followed
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
gas under pressure: refrigerated liquefied gas

Results and discussion

pH value
pH value:
3.9
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The determined averaged result for pH of the test substance was 3.9.