Registration Dossier

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, non-adapted
Duration of test (contact time):
28 d

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
6
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
other: not readily biodegradable
Conclusions:
Under the current test condition the test item in not readily biodegradable!
Executive summary:

Under the current test condition the test item in not readily biodegradable!