Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Remarks:
DIN EN ISO 2719
Flash point:
85 °C
Atm. press.:
1 015 hPa

No remarks

Conclusions:
The flash point of the DCT mixture is 85 °C at 1015 hPa.
Executive summary:

The flash point of the DCT mixture is 85 °C at 1015 hPa as determined experimentally with the EC method A.9 (closed cup, DIN EN ISO 2719).

Description of key information

The flash point of the DCT mixture is 85 °C at 1015 hPa as determined experimentally with the EC method A.9 (closed cup, DIN EN ISO 2719; Heinz, Krasemann, 2010). This result is comparable to the flash points for the individual DCT isomers which are in the range of 86 °C - 95 °C as reported in the supporting study (Ullmann, 2006).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
85 °C

Additional information