Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-04-20
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
other: DIN EN ISO/IEC 17025
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Purity: 98.8 %
Batch no. 11191230
Percentile:
other: Mean
Mean:
926.2 µm
St. dev.:
469.6
Percentile:
D90
Mean:
1 644 µm
Remarks on result:
other: St.dev. not given
Percentile:
D50
Mean:
967 µm
Remarks on result:
other: St.dev. not given
Percentile:
D10
Mean:
348 µm
Remarks on result:
other: St.dev. not given
Percentile:
other: D1.15
Mean:
ca. 47.94 µm
Remarks on result:
other: A proportion of 1.15 % of the particles have an average particle size of 47.94 µm

 

Particle size [µm]

Proportion [%]

1st measurement

47.94

1.23

2nd measurement

47.94

1.19

3rd measurement

47.94

1.04

Average

47.94

1.15

Conclusions:

The particle size distribution (volume distribution) of methacrylamide was measured by laser diffraction with dry dispersing.
The dustiness of the substance is low.
However, as a significant proportion of particles (> 1 %) have a diameter below 50 µm, inhalation is considered as a relevant exposure pathway.
Executive summary:

The particle size distribution (volume distribution) of methacrylamide was measured by laser diffraction with dry dispersing.

The average of three measurements is: d90: 1644 µm; d50: 967 µm; d10: 348 µm;

A proportion of 1.15 % has a diameter of 47.94 µm (d1.15: 47.94 µm).

The dustiness of the substance is low.

However, as a significant proportion of particles (> 1 %) have a diameter below 50 µm, inhalation is considered as a relevant exposure pathway (cf ECHA Guidance R.14, page 110).

Description of key information

The average of three measurements is: d90: 1644 µm; d50: 967 µm; d10: 348 µm;

A proportion of 1.15 % has a diameter of 47.94 µm (d1.15: 47.94 µm).

The dustiness of the substance is low.

However, as a significant proportion of particles (> 1 %) have a diameter below 50 µm, inhalation is considered as a relevant exposure pathway (cf ECHA Guidance R.14, page 110).

Additional information