Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Additional physico-chemical information

Currently viewing:

Administrative data

Endpoint:
minimum ignition energy
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: According to guideline, but not GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: VDI 2263, Part 1 (May 1990) Dust Fires and Dust Explosions, Hazards – Assessment - Protective Measures, Test Methods for the Determination of Safety Characteristic of Dusts.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2,2',2'-tetrakis(hydroxymethyl)-3,3'-oxydipropan-1-ol
EC Number:
204-794-1
EC Name:
2,2,2',2'-tetrakis(hydroxymethyl)-3,3'-oxydipropan-1-ol
Cas Number:
126-58-9
Molecular formula:
C10H22O7
IUPAC Name:
2,2'-[oxybis(methylene)]bis[2-(hydroxymethyl)propane-1,3-diol]
Details on test material:
Di-Pentaerythritol Standard product; Perstorp ID 0808-BHN-DIP-67470312. median particle size=115.1 µm.

Results and discussion

Results:
The Minimum Ignition Energy (M.I.E) without inductivity for the sample “Di-Pentaerythritol Standard product; Perstorp ID 0808-BHN-DIP-67470312” is determined with 10 mJ

Applicant's summary and conclusion

Conclusions:
The Minimum Ignition Energy (M.I.E) without inductivity for the sample “Di-Pentaerythritol Standard product; Perstorp ID 0808-BHN-DIP-67470312” was determined with 10 mJ(2) Klais, O.; H. Franke; M. Glor; B. Maurer und C.-D. Walther: Vermeiden von Zundquellen als vorbeugender Explosionsschutz,
VDI-Berichte Nr. 975, S. 543-560, VDI-Verlag, Dusseldorf 1992.
Assessment criteria:
M.I.E. >=10 mJ: normally ignitable
3<=M.I.E.< 10 mJ: especially ignitable
M.I.E. < 3 mJ: extremely ignitable
Executive summary:

The Minimum Ignition Energy (M.I.E) without inductivity for the sample “Di-Pentaerythritol Standard product; Perstorp ID 0808-BHN-DIP-67470312” was determined with 10 mJ<M.I.E.<30 mJ. Therefore, the dust is specified according to the literature (2) as “normally ignitable”.

(2) Klais, O.; H. Franke; M. Glor; B. Maurer und C.-D. Walther: Vermeiden von Zundquellen als vorbeugender Explosionsschutz,

VDI-Berichte Nr. 975, S. 543-560, VDI-Verlag, Dusseldorf 1992.

Assessment criteria:

M.I.E. >=10 mJ: normally ignitable

3<=M.I.E.< 10 mJ: especially ignitable

M.I.E. < 3 mJ: extremely ignitable