Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-04-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Similar to EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density). Bulk density according to DIN ISO 60 standards.
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Version / remarks:
and according to DIN ISO 60
Deviations:
no
Principles of method if other than guideline:
Karg bulk density testing device.
GLP compliance:
no
Remarks:
Not required by the authority
Type of method:
other: Bulk density

Test material

Constituent 1
Chemical structure
Reference substance name:
2'-chloroacetoacetanilide
EC Number:
202-269-1
EC Name:
2'-chloroacetoacetanilide
Cas Number:
93-70-9
Molecular formula:
C10H10ClNO2
IUPAC Name:
2'-chloroacetoacetanilide
Details on test material:
Date of expiry: Extended to 1.8.2010 (as tested by LC/MS and IR)
Storage: RT
Identity: Confirmed by NMR, IR-and mass spectrometry (LC/MS)
Appearance: White powder
Odour: Non-specific

Results and discussion

Density
Type:
bulk density
Density:
0.52 other: g/mL
Temp.:
23 °C

Applicant's summary and conclusion

Conclusions:
Bulk density of the test item is measured 0,52 g/mL at 23°C.
Executive summary:

The density study was performed similar to EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density). Bulk density according to DIN ISO 60 standards.

Bulk density of the test item is measured 0,52 g/mL at 23°C with a karg bulk density testing device according to DIN ISO 60 standards.